Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Trials ; 20(1): 562, 2019 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-31511055

RESUMO

BACKGROUND: Interval training in deep water running (DWR-IT) is a training method to improve cardiovascular fitness, functional health, and quality of life and to help control body weight. Its main advantages are the reduction of joint overload and a low risk of musculoskeletal injuries. The aim of the study is to investigate the influence of DWR-IT on functional capacity, body composition, and quality of life of overweight middle-aged adults. METHODS: This is a randomized controlled, two-arm, open, parallel clinical trial with overweight adults. Volunteers will be allocated to a water group (WG), which will be submitted to the intervention, or a control group, which will not be subjected to any kind of intervention. The evaluation will be composed of anamnesis, electrical bioimpedance, six-minute walk test (6MWT), questionnaire on the Impact of Weight on Quality of Life-lite (IWQOL-LITE), Pittsburgh Sleep Quality Index, Epworth Sleepiness Scale, chair stand test, arm curl test, and food frequency questionnaire. The DWR-IT will last for 12 weeks, systematically increasing the intensity and training volume. DISCUSSION: The objective of this clinical trial is to evaluate the effect of DWR-IT on overweight adults. The study is guided through practice based on scientific evidence for the use of training and aquatic rehabilitation. It is expected that after 12 weeks of aquatic intervention there will be a decrease in body fat by about 10%, evaluated by electrical bioimpedance, an increase of about 25% of cardiorespiratory endurance, evaluated by 6MWT, and an improvement of about 25% of physical function domains, self-esteem, distress in public places, and work, analyzed by IWQOL-LITE in the WG. TRIAL REGISTRATION: The study protocol was published in the Brazilian Registry of Clinical Trials (ReBEC) on June 16, 2016. Registration number: RBR-6dmh7d.


Assuntos
Composição Corporal , Terapia por Exercício/métodos , Hidroterapia/métodos , Sobrepeso/terapia , Desempenho Físico Funcional , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sobrepeso/fisiopatologia , Sobrepeso/psicologia , Corrida
2.
Rev. bras. med. esporte ; 25(4): 316-321, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1013653

RESUMO

ABSTRACT Introduction: Regular physical activity prevents cardiovascular diseases (CVD) and atherosclerosis, in addition to improving lipid levels and functional capacity in older adults. Objective: To evaluate and compare the lipid levels, functional performance and ankle brachial index (ABI) of sedentary and active older adults. Methods: This was a comparative cross-sectional study with 84 elderly (≥60 years) male and female subjects, divided into two groups: sedentary group (SG, n = 50) and active group (AG, n = 34) according to the International Physical Activity Questionnaire (IPAQ). Anthropometric and hemodynamic assessments, ankle brachial index (ABI) calculations, and functionality tests (Short Physical Performance Battery - SPPB and 6-minute walking test - 6MWT) were performed. The Shapiro-Wilk normality test was also used, and we conducted the Student's-t and Mann-Whitney tests for the intergroup comparison. For the categorical data, we used Fisher's exact test (p <0.05). Results: Higher values of high-density lipoprotein cholesterol (HDL-c) (p = 0.001) and lower triglycerides (TG) (p = 0.007) were found in AG compared to SG. In the ABI evaluation, AG presented better right (p = 0.012), left (p = 0.015) and end (p = 0.004) ABI rates when compared to SG. AG had better results in functional performance in the SPPB evaluation (p = 0.0007) and in the 6MWT with a greater distance covered (p = 0.0027). In the anthropometric measurements, AG had lower body mass index (BMI) (0.041) and a smaller abdominal circumference (WC) (0.029). In terms of the incidence of referred diseases, intergroup results were only different for hypertension (0.029), while AG had a lower incidence of hypertension. Conclusion: Active older adults had better lipid levels, higher ABI levels, better functional performance, lower body mass, a smaller abdominal circumference, and lower incidence of hypertension, in comparison to sedentary subjects. Level of evidence I; High quality prospective study.


RESUMO Introdução: A prática de atividade física regular previne doenças cardiovasculares (DCV) e aterosclerose, além de melhorar o perfil lipídico e a capacidade funcional em idosos. Objetivo: Avaliar e comparar o perfil lipídico, desempenho funcional e índice tornozelo-braquial (ITB) de idosos sedentários e ativos. Métodos: Trata-se de um estudo comparativo e transversal com 84 idosos (≥ 60 anos) de ambos os sexos, divididos em dois grupos: grupo sedentário (GS, n= 50) e grupo ativo (GA, n= 34) segundo o Questionário Internacional de Atividade Física (IPAQ). Foram realizadas avaliações antropométricas, hemodinâmicas, índice tornozelo-braquial (ITB) e testes de funcionalidade (Short Physical Performance Battery - SPPB e teste de caminhada de 6 minutos - TC6). Além disso, foi utilizado o teste de normalidade Shapiro-Wilk e na comparação entre os grupos utilizou-se o teste t-Student e o teste Mann-Whitney. Já para os dados categóricos, utilizou-se o teste exato de Fisher (p<0,05). Resultados: Foi verificado no GA valores maiores da lipoproteína de alta densidade (high-density lipoprotein cholesterol, HDL-c) (p = 0,001) e menores de triglicerídeo (TG) (p = 0,007) quando comparados ao GS. Na avaliação ITB, observou-se que o GA apresentou melhores índices de ITB direito (p = 0,012), esquerdo (p = 0,015) e final (p = 0,004) quando comparado ao GS. Houve melhores resultados do GA no desempenho funcional na avaliação SPPB (p = 0,0007) e no TC6 com maior distância percorrida (p = 0,0027). Nas medidas antropométricas, o GA apresentou menor índice de massa corporal (IMC) (0,041) e circunferência abdominal (CA) (0,029). Na incidência das doenças referidas, apenas a hipertensão apresentou resultados diferentes entre os grupos (0,029), sendo que o GA teve menor incidência de hipertensão. Conclusão: Os idosos ativos apresentaram melhor perfil lipídico, maiores níveis de ITB, melhor desempenho funcional, além de menor massa corpórea, menor circunferência abdominal e menor incidência de hipertensão em comparação aos sedentários. Nível de evidência I; Estudo prospectivo de alta qualidade.


RESUMEN Introducción: La práctica de actividad física regular previene enfermedades cardiovasculares (ECV) y aterosclerosis, además de mejorar el perfil lipídico y la capacidad funcional en adultos de la tercera edad. Objetivo: Evaluar y comparar el perfil lipídico, desempeño funcional e índice tobillo-braquial (ITB) en adultos de la tercera edad sedentarios y activos. Métodos: Se trata de un estudio comparativo y transversal, con 84 adultos de la tercera edad (≥ 60 años) de ambos sexos, divididos en dos grupos: grupo sedentario (GS, n = 50) y grupo activo (GA, n = 34) según el Cuestionario Internacional de Actividad Física (IPAQ). Fueron realizadas evaluaciones antropométricas, hemodinámicas, índice tobillo-braquial (ITB) y tests de funcionalidad (Short Physical Performance Battery - SPPB y Test de Caminata de 6 minutos - TC6). Además, se utilizó el test de normalidad Shapiro-Wilk y en la comparación entre los grupos se usó el test t-Student y el test Mann-Whitney. Ya para los datos categóricos se usó el test exacto de Fisher (p <0,05). Resultados: Se verificaron en el GA valores mayores de lipoproteína de alta densidad (high-density lipoprotein cholesterol, HDL-c) (p = 0,001) y menores de triglicéridos (TG) (p = 0,007) cuando comparados al GS. En la evaluación ITB, se observó que el GA mostró mejores índices de ITB derecho (p = 0,012), izquierdo (p = 0,015) y final (p = 0,004) cuando comparado al GS. Hubo mejores resultados del GA en el desempeño funcional en la evaluación SPPB (p = 0,0007) y en el TC6 con mayor distancia recorrida (p = 0,0027). En las medidas antropométricas, el GA presentó menor índice de masa corporal (IMC) (0,041) y circunferencia abdominal (CA) (0.029). En la incidencia de las enfermedades referidas, sólo la hipertensión presentó resultados diferentes entre los grupos (0.029), siendo que el GA tuvo menor incidencia de hipertensión. Conclusión: Los adultos de la tercera edad activos presentaron mejor perfil lipídico, mayores niveles de ITB, mejor desempeño funcional, además de menor masa corpórea, menor circunferencia abdominal y menor incidencia de hipertensión en comparación a los sedentarios. Nivel de evidencia I; Estudio prospectivo de alta calidad.

3.
Artigo em Português | LILACS | ID: biblio-1050664

RESUMO

Introdução: DWR-IT é um método de treinamento que visa melhorar a capacidade funcional, aptidão física e qualidade de vida, além de contribuir para controle da obesidade. Objetivo: investigar a influência do DWR-IT na composição corporal, circunferência abdominal, qualidade de vida, capacidade funcional, força e resistência muscular em mulheres obesas de meia idade. Método: trata-se de um estudo piloto de ensaio clínico não controlado, do tipo antes e depois. Foi avaliada a circunferência abdominal, a composição corporal e aplicados 6MWT, CST, ACT e IWQOL-LITE pré e pós-intervenção em sete mulheres obesas de meia idade. O período da intervenção foi de 10 semanas com frequência de três dias por semanas. Resultados e Discussão: houve redução da circunferência abdominal (de 94,71 ± 8,32 cm para 88,43 ± 6,29cm) e da massa gorda (29,50 ± 4,35 kg para 26,47 ± 4,85 kg),aumento da força e resistência muscular dos membros superiores (de 12,86 ±3,44 para 22,71 ±5,71 repetições) e inferiores (de10, 43 ± 2,30 para 14,14±2,67 repetições) e melhora nos domíniosfunção física (de 38,0; 37,0 - 45,0 para 47,00; 46,0 -49,50) e autoestima (de 27,00; 26,50-27,50 para 30,00; 28,0-33,00) do questionário IWQOL-LITE. Conclusão: 10 semanas de DWR-IT foramefetivas em promover melhora da composição corporal, da força eresistência muscular, da função física, da autoestima e melhoras em relação ao sobrepeso e obesidade.


Introduction: DWR-IT is a training method that aims to improve functional capacity, physical fitness and quality of life, in addition to contribute to the control of obesity. Objective: the objective was to investigate the influence of DWR-IT on body composition, abdominal circumference, quality of life, functional capacity, strength and muscular endurance in obese middle-aged women. Methods: this is a pilot study of an uncontrolled clinical trial, before and after. Abdominal circumference, body composition, and the application of 6MWT, CST, ACT and IWQOL-LITE were evaluated before and after intervention in seven obese middle-aged women. The intervention period lasted 10 weeks with a frequency of three days per week. Results and Discussion: there was a reduction in abdominal circumference (94.71 ± 8.32 cm for 88.43 ± 6.29 cm) and fat mass (29.50 ± 4.35 kg for 26.47 ± 4.85 kg), increase of muscle strength and endurance of the upper limbs (from 12.86 ± 3.44 to 22.71 ± 5.71 repetitions) and lower limbs (from 10.43 ± 2.30 to 14.14 ± 2.67 repetitions) and improvement in the physical function domains (from 38.0; 37.0 - 45.0 to 47.00; 46.0 - 49.50) and self-esteem (from 27.00 to 26.50-27.50 for 30.00; 28.0-33.00) in the IWQOL-LITE questionnaire. Conclusion: ten weeks of DWR-IT were effective to promote the improvement of body composition, strength and muscular endurance, physical function and self-esteem, and the improvement in overweight and obesity.


Assuntos
Feminino , Pessoa de Meia-Idade , Hidroterapia , Obesidade
4.
Fisioter. Mov. (Online) ; 30(3): 509-517, July-Sept. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-892008

RESUMO

Abstract Introduction: The peak expiratory flow (PEF) is a practical method that evaluates the caliber of the proximal airways. The ease in handling and the low cost of portable PEF meters made their use frequent. However, few studies have examined the correlation between the different equipment and compared their reference values. Objective: Analyze the correlation of three portable meters of PEF and check if the reference values are applicable in the studied population. Methods: 168 healthy individuals, of both genders, ranging in age from 20 to 80 years, had their PEF measured in Mini-Wright®, Assess® and AirZone® and the values obtained were compared to those predicted by Leiner et al. (1963) and Nunn and Gregg (1989). Statistical analysis was performed by the Kolmogorov-Smirnov tests, ANOVA, Wilcoxon test, Spearman correlation and analysis of agreement of Bland-Altman (p< 0.05). Results: There was significant difference in the values of PEF obtained between the Mini-Wright® and Assess® meters in both genders, between the AirZone® and Assess® only in men and between the Mini-Wright® and AirZone® only in women. The predicted values in the three meters have overestimated the obtained in both genders; there was no correlation between the values obtained from three meters due to the great variation of agreement limits and large interindividual variation. Conclusion: The values obtained in the three meters are not interchangeable and the predicted values were unsuitable for the sample.


Resumo Introdução: O pico de fluxo expiratório (PFE) é um método acessível que avalia o calibre das vias aéreas proximais. A facilidade no manuseio e o baixo custo dos medidores portáteis de PFE tornaram seu uso frequente, entretanto, poucos estudos analisaram a concordância entre os diferentes equipamentos e compararam seus valores de referência. Objetivo: Analisar a concordância de três medidores portáteis de PFE e verificar se os valores de referência são aplicáveis na população estudada. Métodos: 168 indivíduos saudáveis, de ambos os gêneros, na faixa etária de 20 a 80 anos, realizaram medidas de PFE nos aparelhos Mini-Wright®, Assess® e AirZone® e comparou-se os valores obtidos aos previstos por Leiner et al. (1963) e Nunn e Gregg (1989). A análise estatística foi realizada pelos testes Kolmogorov-Smirnov, ANOVA, teste de Wilcoxon, correlação de Spearman e análise de concordância de Bland-Altman (p<0,05). Resultados: Constatou-se diferença significativa nos valores de PFE obt idos entre os medidores Mini-Wright® e Assess® em ambos os gêneros, entre o AirZone® e o Assess® apenas nos homens e entre o Mini-Wright® e o AirZone® somente nas mulheres, sendo que os valores previstos nos três aparelhos superestimaram os obtidos em ambos os gêneros; não se verificou concordância entre os valores obtidos dos três medidores devido à grande variação dos limites de concordância e grande variação interindividual. Conclusão: Os valores obtidos nos três medidores não são intercambiáveis e os valores previstos se mostraram inadequados para a amostra estudada.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Testes de Função Respiratória , Pico do Fluxo Expiratório , Medidores de Velocidade , Valores de Referência , Análise de Variância , Especialidade de Fisioterapia
5.
Fisioter. Mov. (Online) ; 30(2): 207-217, Apr.-June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891989

RESUMO

Abstract Introduction: Therapy choice and its progression for patients with Chronic Obstructive Pulmonary Disease (COPD) should be based on their symptoms and clinical condition according to reports of dyspnea and fatigue. Therefore patient-reported scales have presented a key role during the communication with the patient. Objective: To verify if patients with COPD prefer the Modified Borg Scale (MBS), Visual Analogue Scale (VAS), Glasses Scale (GS), Faces Scale (FS) or Ratings of Perceived Exertion (RPE) during the six-minute walk test(6MWT), and to compare and correlate the scales with each other, with peripheral oxygen saturation (SpO2) and heart rate (HR). Methods: 28 patients with COPD (50% had mild to moderate COPD and 50% had severe to very severe) were evaluated by a respiratory and cognitive assessment. Additionally, they performed the 6MWT, in which the scales were applied simultaneously (random order) and patients reported their preference in the end of the test. Results: 57% of patients were illiterate or presented incomplete primary education and most of them (67%) chose the FS or GS. Significant positive correlations were observed between instruments for both dyspnea and fatigue in the end of the 6MWT, which the strongest was between MBS and FS (r = 0.95). Nevertheless, there was no correlation between the scales and SpO2 and HR. Conclusion: As the majority of patients preferred pictured to numerical scales we suggest their use as a resource for therapeutic evaluation; MBS might be replace by FS, even though they have different scores and not scaled proportionally. However, this change must be carefully considered because there is the risk of dubious interpretation.


Resumo Introdução: A escolha terapêutica e sua progressão ao intervir em pacientes com Doença Pulmonar Obstrutiva Crônica (DPOC) devem ser baseadas nos seus sintomas e quadro clínico, considerando relatos de dispneia e fadiga; assim, escalas perceptivas assumem papel fundamental na comunicação com o paciente. Objetivo: Verificar se pacientes com DPOC preferem a Escala de Borg Modificada (EBM), Escala Visual Analógica (EVA), Escala de Copos (EC), Escala de Faces (EF) ou Ratings of perceived exertion (RPE) durante o teste de caminhada de seis minutos (TC6), bem como comparar e correlacionar as escalas entre si e com saturação periférica de oxigênio e frequência cardíaca. Métodos: Foram avaliados 28 pacientes com DPOC (50% deles com DPOC leve a moderada e 50% com DPOC grave a muito grave) por meio de uma avaliação respiratória e cognitiva, além do TC6, onde aplicou-se as escalas simultaneamente em ordem aleatória, posteriormente o paciente indicou sua escala preferida. Resultados: 57% dos pacientes eram analfabetos ou com ensino fundamental incompleto e a maioria (67%) elegeu a EF ou EC. Correlações positivas significantes foram observadas interinstrumentos tanto para dispneia quanto para fadiga nos membros inferiores ao final do TC6, sendo mais forte entre EBM e EF (r = 0,95). Entretanto, não foi observada correlação significante entre as escalas e a SpO2 e FC. Conclusão: Como a maioria dos pacientes preferiu escalas caricaturizadas às numéricas, sugerimos inseri-las como recurso de avaliação terapêutica; é possível substituir a EBM pela EF, ainda que tenham escores diferenciados e não escalonados proporcionalmente, atentando-se ao risco de interpretação dúbia.

6.
Fisioter. Pesqui. (Online) ; 24(1): 9-14, jan.-mar. 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-892090

RESUMO

RESUMO A manovacuometria é um teste simples, rápido e não invasivo por meio do qual a pressão inspiratória máxima (PImáx) e a pressão expiratória máxima (PEmáx) são obtidas, a fim de auxiliar na avaliação muscular respiratória. Atualmente, há grande variedade de modelos e marcas de manovacuômetros, com diferentes diâmetros e comprimentos de traqueias, no entanto, a interferência desses modelos nas medidas obtidas por esses equipamentos necessita de investigação. Desta forma, o objetivo primário deste estudo foi verificar a influência do comprimento de traqueias nas pressões respiratórias máximas, obtidas por meio de manovacuômetro analógico, em indivíduos saudáveis e, secundariamente, se há correlação entre as medidas. Foram avaliados 50 indivíduos, de 18 a 30 anos, de ambos os sexos, por meio da espirometria e manovacuometria. As PImáx e PEmáx foram realizadas com uso de traqueias de mesmo diâmetro interno (0,5 cm) e comprimentos de 30, 60 e 90 cm. Foram observados valores significativamente menores de PImáx obtidos com a traqueia de comprimento de 90 cm comparados às PImáx obtidas com as traqueias de 30 e 60 cm (teste de Friedman's ANOVA com teste de Wilcoxon com ajuste de Bonferroni). As traqueias de 30, 60 e 90 cm de comprimento e mesmo diâmetro não influenciaram os valores de PEmáx e PImáx, exceto a traqueia de 90 cm para os valores de PImáx, o que pode interferir na prática clínica fisioterapêutica. Novos estudos são necessários para analisar a necessidade de padronização do comprimento da traqueia utilizada em manovacuômetros.


RESUMEN La manovacuometría es una prueba sencilla, rápida y no invasiva por la cual se obtienen la presión inspiratoria máxima (PImax) y la presión espiratoria máxima (PEmax), con el objetivo de ayudar en el examen muscular respiratorio. Hoy día se encuentran una gran variedad de modelos y marcas de manovacuometros, con diferentes diámetros y longitudes de las tráqueas, pero hacen falta estudios sobre la interferencia de estos modelos en las mediciones por este instrumento. En este texto se propone examinar en sujetos sanos, en primer lugar, la influencia en la longitud de las tráqueas en las presiones respiratorias máximas, obtenidas por manovacuometros analógicos, y en segundo lugar comprobar la existencia de correlación entre las mediciones. Se evaluaron a cincuenta sujetos entre 18 y 30 años de edad, tanto varones como mujeres, empleando la espirometría y la manovacuometría. Se midió la PImax y la PEmax empleando tráqueas de mismo diámetro interno (0,5 cm) y con longitudes de 30, 60 e 90 cm. Se observaron valores significativamente menores de PImax con la tráquea de longitud de 90 cm en comparación con las PImax con las tráqueas de 30 y 60 cm (prueba de Friedman's ANOVA, la de Wilcoxon con ajustes de Bonferroni). Las tráqueas de 30, 60 y 90 cm de longitud y mismo diámetro no influyeron en los valores de la PEmax y de la PImax, con excepción de la tráquea de 90 cm en los valores de la PImax, lo que puede interferir la práctica clínica fisioterapéutica. Se necesitan más estudios para evaluar la necesidad de estándares de la longitud de tráqueas empleadas en manovacuometros.


ABSTRACT Manovacuometry is a simple, fast, and non-invasive test, with maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) obtained to assist respiratory muscle assessment. Currently, there is a wide variety of models and brands of manovacuometers with different trachea diameters and lengths. However, the interference of these models in the measurements obtained by these equipments needs to be investigated. Thus, this study mainly aimed to verify the influence of tracheal length on maximal respiratory pressures (MRP), obtained by an analog manovacuometer, in healthy individuals. Our secondary objective was to verify the correlation between measurements. Fifty individuals, aged 18 to 30, of both sexes, were evaluated by spirometry and manovacuometry. MIP and MEP were performed using tracheas with same internal diameter (0.5 cm) and 30 cm, 60 cm, and 90 cm length. Significantly lower MIP values were observed when comparing a 90 cm trachea to 30 and 60 cm tracheas (Friedman's ANOVA test and Wilcoxon test with Bonferroni adjustment). Tracheas with 30, 60, and 90 cm length and same diameter did not affect MIP and MEP values, except the 90 cm trachea for MIP values, which may interfere in the physical therapy clinical practice. Further studies are required to analyze the need for standardizing the trachea length used in manovacuometers.

7.
Fisioter. mov ; 29(4): 731-739, Out.-Dec. 2016. tab
Artigo em Inglês | LILACS | ID: biblio-828787

RESUMO

Abstract Introduction: The "Hiperdia System" sets goals and guidelines to expand prevention, diagnosis, treatment and control of Diabetes Mellitus and Hypertension. Knowing the epidemiological characteristics of the population is important to strengthen public health programs. Objective: The objective of the study was to describe the sociodemographic profile, risk factors and complications of hypertensive, diabetic and hypertensive diabetic people registered in the HiperDia system of the Ministry of Health of the Basic Health Units (Unidades Básicas de Saúde - UBS) in Barra Bonita, São Paulo State. Methods: This is a descriptive cross-sectional study, which used 113 medical records of diabetic and hypertensive patients as a data source for information about gender, age, race, education, marital status, body mass index (BMI), family history, smoking, sedentarism, acute myocardial infarction, stroke, kidney disease, amputation and diabetic foot. Descriptive statistics were used. Results: As a result, the epidemiological profile of patients registered in the HiperDia system was characterized by: a mean age of 57.3 years; 61.9% women, 82.1% Caucasians, 66.4% with education level up to incomplete primary education, 48.5% lived with partners and children, 19.5% were smokers, 51.4% were sedentary, 44.3% were overweight and obese and 69% had a diagnosis of hypertension and diabetes. Conclusion: The results were relevant allowing professionals and health managers to institute preventive programs to intervene in the risk factors involved in the genesis and complications of hypertension and diabetes.


Resumo Introdução: O Sistema Hiperdia estabelece metas e diretrizes para ampliar ações de prevenção, diagnóstico, tratamento e controle do Diabetes Mellitus e Hipertensão Arterial. Conhecer as características epidemiológicas da população é importante para fortalecer programas de saúde pública. Objetivo: O objetivo do estudo foi descrever o perfil sociodemográfico, fatores de risco e complicações dos hipertensos, diabéticos e hipertensos diabéticos cadastrados no sistema HiperDia do Ministério da Saúde das Unidades Básicas de Saúde (UBS) do município de Barra Bonita, São Paulo. Métodos: Trata-se de um estudo transversal descritivo, utilizando como fonte de dados 113 prontuários dos diabéticos e hipertensos, dos quais foram coletadas informações sobre: sexo, idade, cor da pele, escolaridade, situação conjugal, índice de massa corporal (IMC), antecedentes familiares, tabagismo, sedentarismo, infarto agudo do miocárdio, AVE, doença renal, pé diabético e amputação. Foi utilizada estatística descritiva. Resultados: Como resultados notou-se que o perfil epidemiológico dos pacientes cadastrados no Sistema HiperDia foi caracterizado por: média de idade de 57,3 anos, 61,9% de mulheres, 82,1% de indivíduos da raça branca; 66,4% com escolaridade até o fundamental incompleto e 48,5% convivia com companheiros e filhos; 19,5% tabagistas; 51,4% sedentários e 44,3% sobrepesos e obesos e 69% apresentavam diagnóstico de hipertensão e diabetes. Conclusão: Os resultados se mostraram relevantes no sentido de permitir que os profissionais e gestores em saúde possam instituir programas preventivos visando intervir nos fatores de risco envolvidos com a gênese e complicações da HAS e do DM.

8.
Rev. bras. ciênc. mov ; 23(2): 104-112, 2015. tab, ilus
Artigo em Português | LILACS | ID: biblio-833714

RESUMO

São escassos os relatos encontrados na literatura que fazem comparações entre diferentes espirômetros de incentivo (EI) e há diferenças nos métodos adotados. Assim, os objetivos do estudo foram comparar o efeito dos EI a fluxo Cliniflo® com fluxo pré-determinado e a volume Voldyne® na função pulmonar, mobilidade tóraco-abdominal e força muscular respiratória, assim como analisar as características dos protocolos de treinamento baseado na sobrecarga gerada por cada um desses EI em indivíduos saudáveis sedentários. Foram avaliados 20 indivíduos saudáveis sedentários de 18 a 30 anos, de ambos os sexos, distribuídos randomicamente entre dois grupos: grupo Cliniflo® (GC) e grupo Voldyne® (GV) e reavaliados após cinco semanas, por meio da espirometria, manovacuometria e cirtometria dinâmica, e foi calculado o índice de amplitude tóraco-abdominal (IA). Os indivíduos realizaram duas sessões semanais de treinamento muscular respiratório (TMR) durante cinco semanas, totalizando 10 sessões. Na análise intragrupos, no GC verificou-se aumento estatisticamente significativo da capacidade vital e do pico de fluxo expiratório (PFE), e no GV observou-se aumento significativo dos valores de capacidade vital forçada, do PFE e da ventilação voluntária máxima, obtidos pela espirometria. Quanto às pressões inspiratória e expiratória máximas e os IA axilar, xifoidiano e abdominal não foram observadas diferenças significativas em nenhum dos grupos. Quanto à análise intergrupos, também não foi observada diferença significativa entre eles. Conclui-se que o treinamento com EI a fluxo Cliniflo® e a volume Voldyne® proporcionaram melhora das capacidades pulmonares, pico de fluxo e, somente no a volume, na endurance muscular respiratória na amostra estudada. E quanto as características do treinamento, ambos geraram baixa sobrecarga e dessa forma, não caracterizaram-se como treinamentos de força muscular respiratória.(AU)


There are few reports in the literature to make comparisons between differente respiratory spirometer and there are differences in the adopted methods. The objectives of the study were to compare the effect of flow-oriented spirometer Cliniflo® with pre-determined flow and volume-oriented spirometer Voldyne® on the pulmonary function, thoracoabdominal mobility and muscle strength volume, as well as analyze the characteristics of training protocols based the overhead generated by each EI in sedentary healthy individuals. Twenty healthy sedentary individuals were assessed, aged from 18 to 30 years, of both sex, randomly assigned in two groups: Cliniflo® group (CG) and Voldyne® group (VG) and revalued after five weeks, by spirometry, manometer and cirtometry dynamics and was calculated the amplitude thoracoabdominal index (TAI). Subjects performed two weekly sessions of respiratory muscle training (RMT) for five weeks, totaling 10 sessions. . In the intragroup analysis, the CG was found statistically significant increase of vital capacity and peak expiratory flow (PEF), and VG showed a significant increase in the values of forced vital capacity, PEF, and maximal voluntary ventilation, obtained by spirometry. As for the maximal inspiratory and expiratory pressures and TAI axillary, xiphoid and abdominal found no significant differences in either group. As for inter-group analysis, was not significantly different between them. In conclusion, training with the flow-oriented spirometer Cliniflo® and volume-oriented spirometer Voldyne® provided improves lung capacity, peak flow, and only on the volume in respiratory muscle endurance in the study sample. And the training characteristics, generated both low overhead and thus not characterized as respiratory muscle strength training.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Exercícios Respiratórios , Especialidade de Fisioterapia , Músculos Respiratórios , Espirometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...